FLUKE 62 MAX Infrared Thermometer

Fluke 62 MAX. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas
SKU
FLUKE116/62MAX+
Excl. VAT £63.00
£75.60 Incl. VAT

Fluke 62 MAX+ Infrared Thermometer

Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
More Information
Dimensions 167mm x 84mm x 46mm
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account